Perry Machinery Poland Sp. z o.o., Wolności 1a str., 05-850 Ożarów Mazowiecki tel.: +48 22 722 32 70

Product Categories

Quote Cart

Your Cart is Empty.

Washing and Sterilizing Glass Containers Line IMA Hydra 1000 4I Unused

Stock #UG6272

Unused line for washing and sterilizing glass containers by IMA. Consists of linear washer type Hydra 1000 4I with sterillizing tunnel type Blue Galaxy 870FL.
Machines new 2015, designed and manufactured according to cGMP standards.

WASHER DETAILS
– Washer ensures removal of at least 3 types of contamination – particles such as glass, fibres, oxides.
– Working speed up to 3600 containers/hour.
– Size range of containers: diameter from 50 up to 80 mm. Max height 180 mm, min diameter of neck 10 mm.
– Water for injection supply pressure in range 2.5-4 bar (1.5″ Tri-clover clamp).
– Demineralized water supply pressure 2.5-4 bar (1.5″ Tri-clover clamp).
– Compressed air supply pressure 6-10 bar (1.5″ Tri-clover clamp).
– Power supply voltage: 400V, 50 Hz, 3 PH +N +G. Installed power 5 kW. Heat loss 4 kW. Sound emission level <80Db. Height of outlet discharge: 950 mm (+/- 25 mm).
– Shipping dimensions: W 1650 mm x L 3655 mm x H 2000 mm x Weight 1650 kg.

STERILIZING TUNNEL DETAILS
– Sterillizing tunnel type Blue Galaxy 870 FL is working in continuous way and has vertical flow of hot air.
– Working width of the belt: 870 mm. Hot zone has working length 904 mm and has surface 0.787 m2. Cooling zone has length 1044 mm and surface 0.91 m2. Position of belt is at height 950 mm (+/- 25 mm) from ground level.
– Maximum working temperature in heating zone up to 350 C. Temperature in cooling zone 18 C. Final temperature of containers at outlet 25C.
– Power supply: 400 Volt, 50 Hz, 3 PH + N +G. Main power consumption (heating) 40 KW. Cold chamber 24 kW, UPS (fans) 10 kW. Total installed power 74 kW.
– Cooling water, temperature at inlet 9-11C, flow up to 8000 l/h.
– Aspiration at infeed zone 1500 m3/h, air expelled from infeed zone 1400 m3/h. Air supply in heating zone 200 m3/h, temperature in range 30-70C. Recycled air flow rate: heating zone 1860 m3/h, cooling zone 2160 m3/h. Heat lost in the environment – approx 10 kW.
– Dimensions: L 3050 mm x W 2025 mm H 2980 mm x Weight 3400 kg.
– Class 5 air according to ISO 14644 is guaranteed for the entire length of the tunnel.

Location: PL